GoToMeeting
Go to meeting:

Error on starting PDM: the os is not presently configured to run this app

Description

After a Windows update (often due to a Microsoft365 update), at startup the PDM is stuck on the following error message

The operating system is not presently configured to run this application.

This because such update (e.g. Microsoft365 ver. 20204) changed the Access Driver to a version that the operating system is not able to manage.
Here is explained by Microsoft:
https://docs.microsoft.com/da-dk/office/troubleshoot/access/cannot-use-odbc-or-oledb

Solution #1

As suggested in the link above,  the solution is to reinstall the Access Driver

e.g. 2016 MS Access Database Engine Redistributable

 

Here is an example on how the driver can be modified in the process:

Solution #2

Starting from R17sp2.16 a parameter has been added to DBWConn.PAR file for avoiding the creation of Briefcase datasources.

SKIP_CREATION_BRIEFCASE_DSN  1

please refer to official documentation for further details.

Posted in: Operating System, SQL Server/Database